Comparison of the operating range of a wetted-wall column with a packed column for distillation

  • In this paper, a newly designed distillation column consisting of a wetted wall with a rectangular cross section is analyzed and compared with a conventional packed column with regard to the operating range of both apparatuses. As expected, the pressure drop is considerably lower in the wetted-wall column and, therefore, it offers a higher range of operation. However, in the wetted-wall column, the separation efficiency decreases rapidly with increasing F factors. This effect can be overcome by the serial connection of two wetted-wall columns.

Download full text files

Export metadata

Additional Services

Share in Twitter Search Google Scholar
Metadaten
Author:Arnulf ReitzeORCiDGND, Marcus GrünewaldORCiDGND, Julia RieseORCiDGND
URN:urn:nbn:de:hbz:294-99671
DOI:https://doi.org/10.1002/cite.202000065
Parent Title (German):Chemie Ingenieur Technik
Publisher:Wiley-VCH
Place of publication:Hoboken, New Jersey
Document Type:Article
Language:English
Date of Publication (online):2023/06/16
Date of first Publication:2020/10/12
Publishing Institution:Ruhr-Universität Bochum, Universitätsbibliothek
Tag:Fluid dynamics; Pressure drop; Separation efficiency; Small-scale processes; Specialty chemicals
Volume:92
Issue:12,Special Issue: Flexible Apparate und Prozesse
First Page:1968
Last Page:1975
Note:
Dieser Beitrag ist auf Grund des DEAL-Wiley-Vertrages frei zugänglich.
Institutes/Facilities:Lehrstuhl für Fluidverfahrenstechnik
Dewey Decimal Classification:Technik, Medizin, angewandte Wissenschaften / Ingenieurwissenschaften, Maschinenbau
open_access (DINI-Set):open_access
faculties:Fakultät für Maschinenbau
Licence (English):License LogoCreative Commons - CC BY 4.0 - Attribution 4.0 International