Pre-operative risk factors for driveline infection in left ventricular-assist device patients

  • \(\bf Aims\) Implantation of left ventricular-assist devices (LVAD) to treat end-stage heart failure is of increasing relevance due to donor shortage. Infections of the driveline are common adverse events. LVAD infections can lead to high urgency listings for transplantation. However, transplantation in patients with infection leads to worse post-transplantation outcomes. This study aims to evaluate specific risk factors for driveline infections at the time of implantation. \(\textbf {Methods and results}\) Four hundred forty-one patients receiving either Heartmate II or Heartware system from August 2009 to October 2013 were assessed. An expert committee sorted patients into four different groups concerning the likeliness of infection. Twenty-eight (6%) of discussed infection cases were judged as secured, 33 (7%) as likely, 18 (4%) as possible, and 20 (4%) as unlikely. The remaining 342 (78%) subjects showed either no signs of infection at all times (329 [75%]) or developed signs of infection in a second observation period within 1 year after ending of the first observation period (13 [3%]). For a better discriminatory power, cases of secured and likely infections were tested against the group with no infection at all times in a Cox proportional hazard model. Among all variables tested by univariate analysis (significance level \(\it P\) < 0.15), only age (\(\it P\) = 0.07), LVAD-type (\(\it P\) = 0.12), need for another thoracic operation (\(\it P\) = 0.02), and serum creatinine value (\(\it P\) = 0.02) reached statistical significance. These were subsequently subjected to multivariate analysis to calculate the cumulative risk of developing a drive infection. The multivariate analysis showed that of all the potential risk factors tested, only the necessity of re-thoracotomy or secondary thoracic closure had a significant, protective effect (hazard ratio [95% CI] = 0.45 [0.21–0.95]; \(\it P\) = 0.04). \(\bf Conclusion\) This single-centre cohort study shows that driveline infections are common adverse events. The duration of support represents the major risk factor for LVAD driveline infections.

Download full text files

Export metadata

Additional Services

Share in Twitter Search Google Scholar
Metadaten
Author:Ann-Kristin KöhlerGND, Hermann KörperichORCiDGND, Michiel MorshuisORCiDGND, Claudia Christine FreytagGND, Jan GummertORCiDGND, Wolfgang BurchertORCiDGND, Rainer PreußGND, Jan KörferGND
URN:urn:nbn:de:hbz:294-103799
DOI:https://doi.org/10.1002/ehf2.14112
Parent Title (English):ESC heart failure
Publisher:Wiley
Place of publication:Chichester
Document Type:Article
Language:English
Date of Publication (online):2023/11/11
Date of first Publication:2022/08/23
Publishing Institution:Ruhr-Universität Bochum, Universitätsbibliothek
Tag:Open Access Fonds
PET/CT; infection; left ventricular-assist device; risk factor
Volume:9
Issue:6
First Page:3995
Last Page:4002
Note:
Article Processing Charge funded by the Deutsche Forschungsgemeinschaft (DFG) and the Open Access Publication Fund of Ruhr-Universität Bochum.
Institutes/Facilities:Herz- und Diabeteszentrum NRW
Herz- und Diabeteszentrum NRW, Institut für Radiologie, Nuklearmedizin und molekulare Bildgebung
Dewey Decimal Classification:Technik, Medizin, angewandte Wissenschaften / Medizin, Gesundheit
open_access (DINI-Set):open_access
Licence (German):License LogoCreative Commons - CC BY-NC-ND 4.0 - Namensnennung - Nicht kommerziell - Keine Bearbeitungen 4.0 International