Assessment of operator reliability in ultrasound of the median and ulnar nerve using Bland-Altman analysis
- Currently, there is no standardized method to evaluate operator reliability in nerve ultrasound. A short prospective protocol using Bland-Altman analysis was developed to assess the level of agreement between operators with different expertise levels. A control rater without experience in nerve ultrasound, three novices after two months of training, an experienced rater with two years of experience, and a reference rater performed blinded ultrasound examinations of the left median and ulnar nerve in 42 nerve sites in healthy volunteers. The precision of Bland-Altman agreement analysis was tested using the Preiss–Fisher procedure. Intraclass correlation coefficients (ICC), coefficients of variation, and Bland-Altman limits of agreement were calculated. The sample size calculation and Preiss–Fisher procedure showed a sufficient precision of Bland–Altman agreement analysis. Limits of agreement of all trained novices ranged from 2.0 to 2.9 mm\(^{2}\) and were within the test’s maximum tolerated difference. Ninety-five percent confidence intervals of limits of agreement revealed a higher precision in the experienced rater’s measurements. Operator reliability in nerve ultrasound of the median and ulnar nerve arm nerves can be evaluated with a short prospective controlled protocol using Bland–Altman statistics, allowing a clear distinction between an untrained rater, trained novices after two months of training, and an experienced rater.
Author: | Jörg PhilippsORCiDGND, Hannah MorkGND, Maria KatzGND, Mark KnaupGND, Kira BeyerGND, Kristina SpiesGND, Johannes CorbachGND, Peter Dieter SchellingerORCiDGND |
---|---|
URN: | urn:nbn:de:hbz:294-90138 |
DOI: | https://doi.org/10.3390/diagnostics11112134 |
Parent Title (English): | Diagnostics |
Publisher: | MDPI |
Place of publication: | Basel |
Document Type: | Article |
Language: | English |
Date of Publication (online): | 2022/06/01 |
Date of first Publication: | 2021/11/17 |
Publishing Institution: | Ruhr-Universität Bochum, Universitätsbibliothek |
Tag: | Open Access Fonds Bland-Altman agreement analysis; cross-sectional area; nerve ultrasound; reliability; training effect |
Volume: | 11 |
Issue: | 11, Artikel 2134 |
First Page: | 2134-1 |
Last Page: | 2134-8 |
Note: | Article Processing Charge funded by the Open Access Publication Fund of Ruhr-Universität Bochum. |
Institutes/Facilities: | Johannes Wesling Klinikum Minden, Klinik für Neurologie und Neurogeriatrie |
Dewey Decimal Classification: | Technik, Medizin, angewandte Wissenschaften / Medizin, Gesundheit |
open_access (DINI-Set): | open_access |
Licence (English): | Creative Commons - CC BY 4.0 - Attribution 4.0 International |